Technical Specifications
| Input | |||||
| Measured variables | Flow velocity, temperature | ||||
| Nominal diameter&flow rang | Nominal diameter | DN10 | DN15 | DN20 | DN25 |
| Flow range (L/min) | 3~20 | 10~100 | 12~120 | 16~160 | |
| Temperature range | (0~100)℃ | ||||
| Output | |||||
| Transmitter output | Flow/temperature (4~20) mA, load resistance ≤500Ω | ||||
| Alarm output | Flow/temperature alarm, PNP alarm contact, contact capacity: 24V/50mA | ||||
| Communication | RS485 interface, MODBUS-RTU | ||||
| Electrical parameters | |||||
| Power supply | 24VDC | ||||
| Power consumption | <3W | ||||
| Electrical interface | M12*1.5 aviation plug | ||||
| Performance parameters | |||||
| Accuracy | Flow rate: 1.5 levels | ||||
| Temperature: ±1℃ | |||||
| Insulation resistance | 50MΩ at 100VDC | ||||
| Process conditions | |||||
| Media | Liquid (water or water-soluble liquid such as ethylene glycol) | ||||
| Viscosity | ≤68cst | ||||
| Medium temperature | 0℃~100℃ | ||||
| Environmental conditions | |||||
| Environmental conditions | Temperature: -20℃~85℃; Humidity: <95% | ||||
| Protection level | IP65 | ||||
-
Integrated Flow & Temperature Monitoring
Unlike conventional turbine flow meters, the FK-FLM200 integrates:
-
Flow measurement
-
Temperature sensing
This dual-parameter monitoring design allows operators to obtain complete process data from a single compact device, improving efficiency and reducing installation complexity.
-
OLED Smart Display
The meter is equipped with a self-luminous OLED display featuring:
-
Real-time flow rate
-
Cumulative flow
-
Temperature display
-
Alarm indication
The display ensures clear visibility under various lighting conditions and enhances user interaction.
-
Applications
The FK-FLM200 Miniature Turbine Flowmeter is ideal for liquid flow measurement in various industries:
Industrial Liquid Monitoring
-
Process water
-
Cooling water
-
Clean liquids
-
Chemical solutions
Key Industries
-
Petrochemical industry
-
Power plants
-
Metallurgy & steel manufacturing
-
Papermaking
-
Food processing
-
Water treatment systems
-
Battery manufacturing
Its compact size makes it especially suitable for:
-
Skid-mounted equipment
-
OEM machinery
-
Small-diameter pipelines
-
Laboratory and pilot systems
-
Measuring principle
The FK-FLM200 operates based on the turbine rotation principle.
Inside the flowmeter body, a precision magnetic impeller is installed in the measuring tube. When liquid flows through the pipeline, it strikes the impeller blades, causing the impeller to rotate.
The angular velocity of the impeller is directly proportional to the flow rate of the liquid.
As the impeller rotates:
-
The embedded magnet passes a Hall-effect sensor.
-
The sensor generates a pulse signal.
-
The pulse frequency is proportional to the flow rate.
-
The transmitter converts the pulse frequency into a standard electrical signal.
-
The display unit shows instantaneous flow rate and totalized flow.
This pulse-based measurement ensures high repeatability and accurate liquid flow monitoring.
-
Structural Design & Installation
The FK-FLM200 is designed for easy installation and maintenance:
-
Union-type connection for quick removal and replacement
-
Separate electronics and base design for convenient servicing
-
Rotatable display panel (180° adjustment)
-
Flexible cable outlet direction
After removing four screws, the display can be rotated 180°, allowing flexible adaptation to different installation orientations.